Source code for nirfmxgsm.modacc_configuration

"""Provides methods to configure the ModAcc measurement."""

import functools

import nirfmxgsm.attributes as attributes
import nirfmxgsm.enums as enums
import nirfmxgsm.errors as errors
import nirfmxgsm.internal._helper as _helper


def _raise_if_disposed(f):
    """From https://stackoverflow.com/questions/5929107/decorators-with-parameters."""

    @functools.wraps(f)
    def aux(*xs, **kws):
        meas_obj = xs[0]  # parameter 0 is 'self' which is the measurement object
        if meas_obj._signal_obj.is_disposed:
            raise Exception("Cannot access a disposed Gsm signal configuration")
        return f(*xs, **kws)

    return aux


[docs] class ModAccConfiguration(object): """Provides methods to configure the ModAcc measurement.""" def __init__(self, signal_obj): """Provides methods to configure the ModAcc measurement.""" self._signal_obj = signal_obj self._session_function_lock = signal_obj._session_function_lock self._interpreter = signal_obj._interpreter
[docs] @_raise_if_disposed def get_measurement_enabled(self, selector_string): r"""Gets whether to enable modulation accuracy (ModAcc) measurements on the acquired signal. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (bool): Specifies whether to enable modulation accuracy (ModAcc) measurements on the acquired signal. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_MEASUREMENT_ENABLED.value ) attr_val = bool(attr_val) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_measurement_enabled(self, selector_string, value): r"""Sets whether to enable modulation accuracy (ModAcc) measurements on the acquired signal. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. value (bool): Specifies whether to enable modulation accuracy (ModAcc) measurements on the acquired signal. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_MEASUREMENT_ENABLED.value, int(value), ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_measurement_interval(self, selector_string): r"""Gets whether the measurement is performed on a single specified timeslot or across multiple timeslots. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default Value is **'Number of Timeslots'**. +-------------------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +=========================+==========================================================================================================================+ | Number of Timeslots (0) | The measurement includes all timeslots defined by the Num Timeslots attribute. | +-------------------------+--------------------------------------------------------------------------------------------------------------------------+ | Timeslot at Offset (1) | The measurement is performed only on the timeslot specified by the ModAcc Meas Offset attribute. This attribute is | | | applicable only when you set the Trigger Type attribute to **IQ Power Edge** or **Digital Edge **. | +-------------------------+--------------------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ModAccMeasurementInterval): Specifies whether the measurement is performed on a single specified timeslot or across multiple timeslots. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_MEASUREMENT_INTERVAL.value ) attr_val = enums.ModAccMeasurementInterval(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_measurement_interval(self, selector_string, value): r"""Sets whether the measurement is performed on a single specified timeslot or across multiple timeslots. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default Value is **'Number of Timeslots'**. +-------------------------+--------------------------------------------------------------------------------------------------------------------------+ | Name (Value) | Description | +=========================+==========================================================================================================================+ | Number of Timeslots (0) | The measurement includes all timeslots defined by the Num Timeslots attribute. | +-------------------------+--------------------------------------------------------------------------------------------------------------------------+ | Timeslot at Offset (1) | The measurement is performed only on the timeslot specified by the ModAcc Meas Offset attribute. This attribute is | | | applicable only when you set the Trigger Type attribute to **IQ Power Edge** or **Digital Edge **. | +-------------------------+--------------------------------------------------------------------------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ModAccMeasurementInterval, int): Specifies whether the measurement is performed on a single specified timeslot or across multiple timeslots. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ModAccMeasurementInterval else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_MEASUREMENT_INTERVAL.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_measurement_offset(self, selector_string): r"""Gets the offset, relative to the trigger of the timeslot to be measured. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is 0. Valid values are [0, (:py:attr:`~nirfmxgsm.attributes.AttributeID.NUMBER_OF_TIMESLOTS` -1)]. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (int): Specifies the offset, relative to the trigger of the timeslot to be measured. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_MEASUREMENT_OFFSET.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_measurement_offset(self, selector_string, value): r"""Sets the offset, relative to the trigger of the timeslot to be measured. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is 0. Valid values are [0, (:py:attr:`~nirfmxgsm.attributes.AttributeID.NUMBER_OF_TIMESLOTS` -1)]. Args: selector_string (string): Pass an empty string. value (int): Specifies the offset, relative to the trigger of the timeslot to be measured. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_MEASUREMENT_OFFSET.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_averaging_enabled(self, selector_string): r"""Gets whether to enable averaging for the modulation accuracy (ModAcc) measurement. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is **False**. +--------------+---------------------------------------------------------+ | Name (Value) | Description | +==============+=========================================================+ | False (0) | The measurement is performed on a single acquisition. | +--------------+---------------------------------------------------------+ | True (1) | The measurement is averaged over multiple acquisitions. | +--------------+---------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ModAccAveragingEnabled): Specifies whether to enable averaging for the modulation accuracy (ModAcc) measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_AVERAGING_ENABLED.value ) attr_val = enums.ModAccAveragingEnabled(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_averaging_enabled(self, selector_string, value): r"""Sets whether to enable averaging for the modulation accuracy (ModAcc) measurement. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is **False**. +--------------+---------------------------------------------------------+ | Name (Value) | Description | +==============+=========================================================+ | False (0) | The measurement is performed on a single acquisition. | +--------------+---------------------------------------------------------+ | True (1) | The measurement is averaged over multiple acquisitions. | +--------------+---------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ModAccAveragingEnabled, int): Specifies whether to enable averaging for the modulation accuracy (ModAcc) measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ModAccAveragingEnabled else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_AVERAGING_ENABLED.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_averaging_count(self, selector_string): r"""Gets the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxgsm.attributes.AttributeID.MODACC_AVERAGING_ENABLED` attribute to **True**. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is 10. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (int): Specifies the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxgsm.attributes.AttributeID.MODACC_AVERAGING_ENABLED` attribute to **True**. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_AVERAGING_COUNT.value ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_averaging_count(self, selector_string, value): r"""Sets the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxgsm.attributes.AttributeID.MODACC_AVERAGING_ENABLED` attribute to **True**. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is 10. Args: selector_string (string): Pass an empty string. value (int): Specifies the number of acquisitions used for averaging when you set the :py:attr:`~nirfmxgsm.attributes.AttributeID.MODACC_AVERAGING_ENABLED` attribute to **True**. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_AVERAGING_COUNT.value, value ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_droop_compensation_enabled(self, selector_string): r"""Gets whether to enable droop compensation for the modulation accuracy (ModAcc) measurement. Droop compensation allows the ModAcc measurement to minimize the contribution of amplifier power variations to the EVM results. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is **False**. +--------------+-----------------------------------------------------------+ | Name (Value) | Description | +==============+===========================================================+ | False (0) | Disables power droop compensation in the EVM measurement. | +--------------+-----------------------------------------------------------+ | True (1) | Enables power droop compensation in the EVM measurement. | +--------------+-----------------------------------------------------------+ Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (enums.ModAccDroopCompensationEnabled): Specifies whether to enable droop compensation for the modulation accuracy (ModAcc) measurement. Droop compensation allows the ModAcc measurement to minimize the contribution of amplifier power variations to the EVM results. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_DROOP_COMPENSATION_ENABLED.value, ) attr_val = enums.ModAccDroopCompensationEnabled(attr_val) except (KeyError, ValueError): raise errors.DriverTooNewError() # type: ignore finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_droop_compensation_enabled(self, selector_string, value): r"""Sets whether to enable droop compensation for the modulation accuracy (ModAcc) measurement. Droop compensation allows the ModAcc measurement to minimize the contribution of amplifier power variations to the EVM results. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is **False**. +--------------+-----------------------------------------------------------+ | Name (Value) | Description | +==============+===========================================================+ | False (0) | Disables power droop compensation in the EVM measurement. | +--------------+-----------------------------------------------------------+ | True (1) | Enables power droop compensation in the EVM measurement. | +--------------+-----------------------------------------------------------+ Args: selector_string (string): Pass an empty string. value (enums.ModAccDroopCompensationEnabled, int): Specifies whether to enable droop compensation for the modulation accuracy (ModAcc) measurement. Droop compensation allows the ModAcc measurement to minimize the contribution of amplifier power variations to the EVM results. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) value = value.value if type(value) is enums.ModAccDroopCompensationEnabled else value error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_DROOP_COMPENSATION_ENABLED.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_all_traces_enabled(self, selector_string): r"""Gets whether to enable the traces to be stored and retrieved after performing the modulation accuracy (ModAcc) measurement. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (bool): Specifies whether to enable the traces to be stored and retrieved after performing the modulation accuracy (ModAcc) measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_ALL_TRACES_ENABLED.value ) attr_val = bool(attr_val) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_all_traces_enabled(self, selector_string, value): r"""Sets whether to enable the traces to be stored and retrieved after performing the modulation accuracy (ModAcc) measurement. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is FALSE. Args: selector_string (string): Pass an empty string. value (bool): Specifies whether to enable the traces to be stored and retrieved after performing the modulation accuracy (ModAcc) measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_ALL_TRACES_ENABLED.value, int(value), ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def get_number_of_analysis_threads(self, selector_string): r"""Gets the maximum number of threads used for parallelism for the ModAcc measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is 1. Args: selector_string (string): Pass an empty string. Returns: Tuple (attr_val, error_code): attr_val (int): Specifies the maximum number of threads used for parallelism for the ModAcc measurement. error_code (int): Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) attr_val, error_code = self._interpreter.get_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_NUMBER_OF_ANALYSIS_THREADS.value, ) finally: self._session_function_lock.exit_read_lock() return attr_val, error_code
[docs] @_raise_if_disposed def set_number_of_analysis_threads(self, selector_string, value): r"""Sets the maximum number of threads used for parallelism for the ModAcc measurement. The number of threads can range from 1 to the number of physical cores. The number of threads you set may not be used in calculations. The actual number of threads used depends on the problem size, system resources, data availability, and other considerations. You do not need to use a `Selector String <https://www.ni.com/docs/en-US/bundle/rfmx/page/selector-strings-net.html>`_ to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals. The default value is 1. Args: selector_string (string): Pass an empty string. value (int): Specifies the maximum number of threads used for parallelism for the ModAcc measurement. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.set_attribute_i32( updated_selector_string, attributes.AttributeID.MODACC_NUMBER_OF_ANALYSIS_THREADS.value, value, ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def configure_averaging(self, selector_string, averaging_enabled, averaging_count): r"""Configures averaging for the modulation accuracy (ModAcc) measurement. Args: selector_string (string): Pass an empty string. The signal name that is passed when creating the signal configuration is used. averaging_enabled (enums.ModAccAveragingEnabled, int): This parameter specifies whether to enable averaging for the measurement. The default value is **False**. +--------------+---------------------------------------------------------+ | Name (Value) | Description | +==============+=========================================================+ | False (0) | The measurement is performed on a single acquisition. | +--------------+---------------------------------------------------------+ | True (1) | The measurement is averaged over multiple acquisitions. | +--------------+---------------------------------------------------------+ averaging_count (int): This parameter specifies the number of acquisitions used for averaging when you set the **Averaging Enabled** parameter to **True**. The default value is 10. Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") averaging_enabled = ( averaging_enabled.value if type(averaging_enabled) is enums.ModAccAveragingEnabled else averaging_enabled ) updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.modacc_configure_averaging( updated_selector_string, averaging_enabled, averaging_count ) finally: self._session_function_lock.exit_read_lock() return error_code
[docs] @_raise_if_disposed def configure_droop_compensation_enabled(self, selector_string, droop_compensation_enabled): r"""Configures whether to enable droop compensation for the modulation accuracy (ModAcc) measurement. Args: selector_string (string): Pass an empty string. The signal name that is passed when creating the signal configuration is used. droop_compensation_enabled (enums.ModAccDroopCompensationEnabled, int): This parameter specifies whether to enable droop compensation for the ModAcc measurement. Droop compensation allows the ModAcc measurement to minimize the contribution of amplifier power variations to the EVM results. The default value is **False**. +--------------+---------------------------------------------------------------+ | Name (Value) | Description | +==============+===============================================================+ | False (0) | Disables the power droop compensation in the EVM measurement. | +--------------+---------------------------------------------------------------+ | True (1) | Enables the power droop compensation in the EVM measurement. | +--------------+---------------------------------------------------------------+ Returns: int: Returns the status code of this method. The status code either indicates success or describes a warning condition. """ try: self._session_function_lock.enter_read_lock() _helper.validate_not_none(selector_string, "selector_string") droop_compensation_enabled = ( droop_compensation_enabled.value if type(droop_compensation_enabled) is enums.ModAccDroopCompensationEnabled else droop_compensation_enabled ) updated_selector_string = _helper.validate_and_update_selector_string( selector_string, self._signal_obj ) error_code = self._interpreter.modacc_configure_droop_compensation_enabled( updated_selector_string, droop_compensation_enabled ) finally: self._session_function_lock.exit_read_lock() return error_code